NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5
RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU. This entry explains how to confirm the cause, apply the fix, and separate it from adjacent cloud failures.
NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5 means RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU. Preserve the first preceding error, then run the targeted control below.
What this failure is
The literal signature is "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5". It is a infrastructure failure associated with cloud RDMA fabrics and multi-node GPU clusters. The line identifies the failing operation or subsystem, while the surrounding evidence decides whether it is the initiating fault or a downstream symptom.
Is this what broke your run? Paste your log.
You're reading about NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5. Paste your own crash log or traceback below and get the real root cause for YOUR run, not this generic entry. No account, no card. Logs are masked at ingress and never saved to account history.
Want 14 days of full access?
Request a free trial code for unlimited diagnoses, alerts, history, and follow-up questions. No credit card.
Why it happens (the mechanism)
RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU. The failure becomes visible at this call site because the operation first requires the missing resource, valid state, healthy peer, or correct result. Earlier log lines and a known-good control carry more causal value than the final wrapper exception.
What you'll observe
- The workload stops or loses forward progress after emitting "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5".
- A retry on the same configuration reproduces the failure because the causal state has not changed.
- The outer framework exception can hide the rank, node, allocation, or dependency that failed first.
- Increasing timeouts or reducing workload size can suppress the symptom without correcting the cause.
Common symptoms and what they mean
| Symptom | Why it happens |
|---|---|
| NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5 | RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU. |
| The same operation fails at a consistent stage of cloud RDMA fabrics and multi-node GPU clusters. | The decisive evidence is the first log line that precedes "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" and differs from a healthy run. |
| The first related warning appears before the final exception and names the causal subsystem. | A nearby failure remains a competing hypothesis until a control separates configuration, capacity, transport, and hardware causes. |
| A known-good control changes one variable and either reproduces or clears the failure. | RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU. |
Which systems are affected
- cloud RDMA fabrics and multi-node GPU clusters
- production-shaped multi-accelerator workloads
- containerized and bare-metal deployments of the same stack
How to confirm this is the problem
Apply the following checklist to a small reproduction: each box below is a positive signal that you are looking at this exact failure rather than a sibling in the same taxonomy.
- ✓Find the first occurrence of "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" and preserve at least 100 lines before it.
- ✓Identify which rank, node, device, or process emitted the first related warning.
- ✓Compare the failing rank, node, input, or configuration with one known-good control.
- ✓Repeat the same input after the targeted change and require the signature to disappear.
- ✓Resume from resume-training only after the control passes.
Example training logs (fingerprint)
NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5Timestamps and exact values vary across runs, but the pattern. An info-level start, an early WARN, an ERROR carrying the symptom. Is the actual fingerprint you should alert on. The Denpex platform flags this combination automatically.
The fix and the prevention pattern
The root cause is on this page and stays free. A free account adds the exact remediation steps, keeps your diagnoses instead of discarding them, and unlocks the fix on every entry in the encyclopedia.
Sign up free. Unlock the full analysisNo credit card · 3 free diagnoses · Instant access
Why the recommended fix works
Ensure Jumbo Frames are enabled end-to-end. Match `ifconfig` MTU (typically 9000) with the switch port MTU. This changes the condition in the causal diagnosis instead of hiding the outer exception. The repeated control proves ownership before recovery from resume-training.
Code examples
# Preserve evidence before restarting
rg -n -i 'error|exception|timeout|failed' <log-file>
nvidia-smi
python -m torch.utils.collect_env
# Find the exact signature in the complete log
rg -n -F -- "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" <log-file>Adapt the snippet to your framework. The same pattern holds for PyTorch Lightning, Hugging Face Trainer, DeepSpeed, Megatron-LM, and vLLM training wrappers. Where the wrapper exposes a config flag (for examplelr_scheduler_type in Trainer), prefer the flag over the imperative API to keep the schedule declarative and reproducible.
Best practices by model family
| Model / Stack | Recommendation | Notes |
|---|---|---|
| First response | Preserve the first failure | Keep the context before "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" so aggregation does not erase causality. |
| Confirmation | Change one variable | Use a known-good node, rank, input, or configuration as the control. |
| Recovery | Resume from resume-training | Resume only after the literal signature no longer appears in the same control. |
With the fix vs without the fix
| Dimension | With the fix | Without the fix |
|---|---|---|
| Evidence | First preceding error and one controlled comparison | Only the final aggregated exception |
| Fix | Ensure Jumbo Frames are enabled end-to-end. Match `ifconfig` MTU (typically 9000) with the switch port MTU. | Retrying the unchanged workload |
| Exit criterion | "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" is absent in the repeated control | The job happened to run once |
Real engineering notes
“Treat "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" as a search key and an investigation checkpoint, not as proof of every cause associated with the phrase. The high-value evidence is what changed immediately before it and whether the failure follows the workload, node, or configuration.”
Visual fingerprint
literal error captured
|
v
find first preceding failure
|
v
run one known-good control
|
+-- follows workload --> inspect input or configuration
+-- follows node ------> inspect hardware or platform
+-- disappears --------> validate the targeted fixDiagnose this failure in VS Code
Select the traceback or open the failed terminal, then run Denpex locally to see the initiating rank, collateral failures, exact fix, and verification command without uploading the log.
Install the free VS Code extensionNCCL errors in context
NCCL is where a distributed job reports failure, which is not the same as where it failed. The hub lists every common NCCL error next to what it actually indicates, and the environment variables that tell them apart.
Compare every nccl error side by sideRoot cause
- RoCE MTU Mismatch - Packets are being dropped because the node MTU exceeds the switch MTU.
- The decisive evidence is the first log line that precedes "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" and differs from a healthy run.
- A nearby failure remains a competing hypothesis until a control separates configuration, capacity, transport, and hardware causes.
The fix and how to prevent it
Unlock the full remediation runbook
14 days on the Scale plan, up to 50 diagnoses a day. Step-by-step remediation, the RMA evidence payload, and multi-node correlation on your own logs. No card, and it does not roll into a subscription.
Frequently asked questions
Twelve targeted questions that engineers and on-call staff most commonly ask about this failure.
What does "NCCL WARN RoCE MTU mismatch detected local MTU != remote MTU mlx5" mean?
Is this line always the root cause?
What should I collect before restarting?
What is the fastest confirmation?
How do I prevent it from recurring?
Don't just read the fix, diagnose your run
The encyclopedia tells you what went wrong. Denpex tells you what went wrong in YOUR training run. With your logs, your config, and your stack.
Related Infrastructure errors
Dual ISP BGP Route Withdrawal Causing Complete GPU Cloud Region Outage
Infrastructure · critical
Routine UPS Maintenance Triggering Cascading Power and Cooling Failure Across GPU Cloud Region
Infrastructure · critical
Remediation Storm Prevention via Circuit Breaker Pattern in AutoClusters
Infrastructure · high
Network Storage Volume Causing Process Hangs on H100 GPU Nodes