Skip to content

RoCE MTU Mismatch. Completion Error 12 / Vendor Err 129

RoCE MTU mismatches between the NIC and switch cause NCCL RDMA queue-pair errors (completion error 12, vendor error 129). Training hangs or crashes during NCCL init or the first collective. Denpex detects the MTU mismatch from NCCL debug logs and identifies the misconfigured endpoint.

Quick answer

RoCE MTU mismatches between the NIC and switch cause NCCL RDMA queue-pair errors (completion error 12, vendor error 129).

Communication#roce#mtu#infiniband#rdma#nccl#completion-error

What this failure is

RoCE MTU Mismatch. Completion Error 12 / Vendor Err 129 is a Communication failure seen during ML training runs. RoCE MTU mismatches between the NIC and switch cause NCCL RDMA queue-pair errors (completion error 12, vendor error 129). Training hangs or crashes during NCCL init or the first collective. Denpex detects the MTU mismatch from NCCL debug logs and identifies the misconfigured endpoint. Common tags: Roce, Mtu, Infiniband, Rdma.

Live diagnosis, no signup

Is this what broke your run? Paste your log.

You're reading about RoCE MTU Mismatch. Completion Error 12 / Vendor Err 129. Paste your own crash log or traceback below and get the real root cause for YOUR run, not this generic entry. No account, no card. Logs are masked at ingress and never saved to account history.

training_logs.txt
No log to hand? Try one:

3 free diagnoses/day

Want 14 days on the Scale plan?

Request an evaluation code. A verified workplace organization activates up to 50 diagnoses a day, alerts, history, and follow-up questions. No credit card or automatic subscription.

Evaluate one incident

Why it happens (the mechanism)

The NIC MTU (active_mtu from ibstat) does not match the switch port MTU, causing RDMA packet fragmentation or drops that manifest as completion error 12. Vendor error 129 is Mellanox-specific: the NIC's firmware rejected the packet because the MTU exceeded the port's configured maximum. After a switch firmware upgrade, the default MTU may change from 2048 to 4096 without updating the NIC configuration. Docker containers may inherit the host MTU but the RoCE device has a different MTU configured. Taken together, these mechanisms explain why the failure is reproducible, why it tends to surface on specific workloads or scales, and why generic mitigation attempts often fall short without addressing the underlying cause.

What you'll observe

  • NCCL init succeeds but the first all-reduce or all-gather fails with completion error 12
  • Training hangs at NCCL communication with ibv completion errors in dmesg
  • Single-node training works but multi-node RoCE fails immediately

Common symptoms and what they mean

SymptomWhy it happens
NCCL WARN Got completion with error 12, vendor err 129The NIC MTU (active_mtu from ibstat) does not match the switch port MTU, causing RDMA packet fragmentation or drops that manifest as completion error 12
ibv_post_send fails on specific node pairs but not othersVendor error 129 is Mellanox-specific: the NIC's firmware rejected the packet because the MTU exceeded the port's configured maximum
NCCL_DEBUG=INFO shows IB transport errors during channel setupAfter a switch firmware upgrade, the default MTU may change from 2048 to 4096 without updating the NIC configuration
ibstat shows active_mtu 2048 but switch port is configured for 4096 or vice versaDocker containers may inherit the host MTU but the RoCE device has a different MTU configured

Which systems are affected

  • Multi-node training over RoCEv2 (Mellanox ConnectX-5/6/7)
  • AWS EFA-based clusters with custom MTU settings
  • Bare-metal clusters with mixed switch firmware
  • Environments where switch MTU was changed without updating NIC MTU

How to confirm this is the problem

Use this checklist to test the hypothesis against a small reproduction. No single line proves the root cause, so preserve the preceding events and compare one variable at a time.

  • Reproduce the failure from a clean checkpoint/seed: the symptom must appear without warm-up state from a previous run.
  • Verified signal present: NCCL WARN Got completion with error 12, vendor err 129
  • Verified signal present: ibv_post_send fails on specific node pairs but not others
  • Verified signal present: NCCL_DEBUG=INFO shows IB transport errors during channel setup
  • Verified signal present: ibstat shows active_mtu 2048 but switch port is configured for 4096 or vice versa
  • A targeted fix from the "How to fix it" section eliminates or substantially reduces the symptom within one validation pass.

The fix and the prevention pattern

The root cause is on this page and stays free. A free account adds the exact remediation steps, saved history, and the fix on every entry in the encyclopedia.

Sign up free. Unlock the full analysis

No credit card. Daily allowance follows verified trust tier. Instant access.

Diagnose this failure in VS Code

Select the traceback or open the failed terminal, then run Denpex locally to see the initiating rank, collateral failures, exact fix, and verification command without uploading the log.

Install the free VS Code extension

NCCL errors in context

NCCL is where a distributed job reports failure, which is not the same as where it failed. The hub lists every common NCCL error next to what it actually indicates, and the environment variables that tell them apart.

Compare every nccl error side by side

Root cause

  • The NIC MTU (active_mtu from ibstat) does not match the switch port MTU, causing RDMA packet fragmentation or drops that manifest as completion error 12
  • Vendor error 129 is Mellanox-specific: the NIC's firmware rejected the packet because the MTU exceeded the port's configured maximum
  • After a switch firmware upgrade, the default MTU may change from 2048 to 4096 without updating the NIC configuration
  • Docker containers may inherit the host MTU but the RoCE device has a different MTU configured

The fix and how to prevent it

Evaluate Denpex on your own logs

Request a Scale evaluation code. A verified workplace organization activates 14 days with up to 50 diagnoses a day. Every account keeps its current diagnosis allowance and gets a verification path. No card or automatic subscription.

We send a single-use code tied to that address. Static provider and TLD rules do not reject valid addresses. Account trust determines the benefit after signup.

Don't just read the fix, diagnose your run

The encyclopedia tells you what went wrong. Denpex tells you what went wrong in YOUR training run. With your logs, your config, and your stack.