NVIDIA Xid 74 - NVLink Fatal Error
A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination.
A physical hardware fault on the NVLink connection between GPUs.
- Symptom
RuntimeError: NCCL error in: ../torch/csrc/distributed/c10d/ProcessGroupNCCL.cpp- Root cause
- A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination.
- Recommended fix
- Reset GPUs sudo nvidia-smi -r Attempts to re-initialize the GPUs and the NVLink fabric.
- How Denpex helps
- Denpex matches NVIDIA Xid 74 - NVLink Fatal Error across every rank in a distributed run and reports which rank failed first, so you act on the initiating node instead of the loudest one.
What this failure is
NVIDIA Xid 74 - NVLink Fatal Error is a Hardware failure seen during ML training runs. A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination. Common tags: Xid Error.
Is this what broke your run? Paste your log.
You're reading about NVIDIA Xid 74 - NVLink Fatal Error. Paste your own crash log or traceback below and get the real root cause for YOUR run, not this generic entry. No account, no card. Logs are masked at ingress and never saved to account history.
Want 14 days on the Scale plan?
Request an evaluation code. A verified workplace organization activates up to 50 diagnoses a day, alerts, history, and follow-up questions. No credit card or automatic subscription.
Why it happens (the mechanism)
Often presents as a software timeout in PyTorch/NCCL. Engineers may attempt to tune NCCL environment variables like NCCL_DEBUG or timeout settings, ignoring the hardware fault.
What you'll observe
- NVRM: Xid (PCI:0000:xx:xx): 74, NVLink Fatal Error
- NCCL WARN NVLink connection failed
- RuntimeError: NCCL error in: ../torch/csrc/distributed/c10d/ProcessGroupNCCL.cpp
Common symptoms and what they mean
| Symptom | Why it happens |
|---|---|
| Multi-GPU distributed training (DDP) hangs indefinitely during AllReduce | A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination. |
| Complete crash of NCCL communication layer | A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination. |
| Possible silent data corruption if the link operates marginally before outright failing | A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination. |
Which systems are affected
- PyTorch
- NCCL
- NVLink
- Hardware
How to confirm this is the problem
Use this checklist to test the hypothesis against a small reproduction. No single line proves the root cause, so preserve the preceding events and compare one variable at a time.
- ✓Run `nvidia-smi nvlink -s` to inspect per-link error statistics
- ✓Check `dmesg -T` for the Xid 74 message to identify the specific GPU pair
Searchable error signature
RuntimeError: NCCL error in: ../torch/csrc/distributed/c10d/ProcessGroupNCCL.cpp
NCCL WARN NVLink connection failedUse this text as a lookup key in logs and upstream issue trackers. It is not presented as a captured customer log. Confirm the cause from your own preceding events, versions, configuration and the cited references.
The fix and the prevention pattern
The root cause is on this page and stays free. A free account adds the exact remediation steps, saved history, and the fix on every entry in the encyclopedia.
Sign up free. Unlock the full analysisNo credit card. Daily allowance follows verified trust tier. Instant access.
Xid 74 in context
Xid 74 is one of a small set of codes the NVIDIA driver uses to report GPU faults, and the number is most of the diagnosis: it tells you whether you are looking at your own code, the driver, or a board that needs replacing.
Compare every Xid code side by sideDiagnose this failure in VS Code
Select the traceback or open the failed terminal, then run Denpex locally to see the initiating rank, collateral failures, exact fix, and verification command without uploading the log.
Install the free VS Code extensionRoot cause
- A physical hardware fault on the NVLink connection between GPUs. This can be caused by signal integrity degradation, mechanical stress, or connector contamination.
The fix and how to prevent it
Evaluate Denpex on your own logs
Request a Scale evaluation code. A verified workplace organization activates 14 days with up to 50 diagnoses a day. Every account keeps its current diagnosis allowance and gets a verification path. No card or automatic subscription.
References
Don't just read the fix, diagnose your run
The encyclopedia tells you what went wrong. Denpex tells you what went wrong in YOUR training run. With your logs, your config, and your stack.