Skip to content

NCCL Random Segfault from Out-of-Order NIC Names

Inconsistent NIC enumeration (e.g. mlx5_3 before mlx5_0) on one node breaks NCCL topology detection and causes random multi-node segfaults; fixed in NCCL 2.23.4.

Quick answer

Inconsistent NIC enumeration (e.

Root cause
One node enumerates NICs out of order. NCCL topology detection assumes ordered NIC names. Out-of-bounds access during NIC setup on the misordered node.
Recommended fix
NCCL_IB_HCA=^mlx5_3
How Denpex helps
Denpex investigates NCCL Random Segfault from Out-of-Order NIC Names using the evidence you provide or your connected workload collects. Earlier rank, host or application evidence is needed to distinguish an initiating failure from a downstream report.
Communication#nccl#infiniband#nic-ordering#segfault#topology#2.23.4

What this failure is

NCCL Random Segfault from Out-of-Order NIC Names is a Communication failure seen during ML training runs. Inconsistent NIC enumeration (e.g. mlx5_3 before mlx5_0) on one node breaks NCCL topology detection and causes random multi-node segfaults; fixed in NCCL 2.23.4. Common tags: Nccl, Infiniband, Nic Ordering, Segfault.

Live diagnosis, no signup

Is this what broke your run? Paste your log.

You're reading about NCCL Random Segfault from Out-of-Order NIC Names. Paste your own traceback and relevant evidence for an investigation of your workload, with a next action or a specific missing fact. A reference entry does not establish your cause. No account or card for the free diagnosis. Review data handling before submitting sensitive logs.

Before uploading, review cloud data handling and local options.

training_logs.txt
No log to hand? Try one:

Upload your log file. Large files are processed in your browser. Only selected evidence is submitted when you run diagnosis.

3 free diagnoses/day

Why it happens (the mechanism)

One node enumerates NICs out of order. NCCL topology detection assumes ordered NIC names. Out-of-bounds access during NIC setup on the misordered node. Taken together, these mechanisms explain why the failure is reproducible, why it tends to surface on specific workloads or scales, and why generic mitigation attempts often fall short without addressing the underlying cause.

What you'll observe

  • Random segfaults during nccl-tests across 4+ H100 nodes
  • Inconsistent. Sometimes works, sometimes crashes
  • Single-node runs are fine

Common symptoms and what they mean

SymptomWhy it happens
Random segfault during multi-node nccl-testsOne node enumerates NICs out of order
ibstat shows out-of-order NIC names (mlx5_3 before mlx5_0)NCCL topology detection assumes ordered NIC names
Out-of-bounds access during NIC setupOut-of-bounds access during NIC setup on the misordered node

Which systems are affected

  • NCCL 2.19+
  • H100 nodes with ConnectX-6 HCAs
  • Multi-node only

How to confirm this is the problem

Use this checklist to test the hypothesis against a small reproduction. No single line proves the root cause, so preserve the preceding events and compare one variable at a time.

  • ✓Reproduce the failure from a clean checkpoint/seed: the symptom must appear without warm-up state from a previous run.
  • ✓Verified signal present: Random segfault during multi-node nccl-tests
  • ✓Verified signal present: ibstat shows out-of-order NIC names (mlx5_3 before mlx5_0)
  • ✓Verified signal present: Out-of-bounds access during NIC setup
  • ✓A targeted fix from the "How to fix it" section eliminates or substantially reduces the symptom within one validation pass.

Root cause

  • One node enumerates NICs out of order
  • NCCL topology detection assumes ordered NIC names
  • Out-of-bounds access during NIC setup on the misordered node

The fix and how to prevent it

The fix and the prevention pattern

The root cause is on this page and stays free. A free account adds the exact remediation steps, saved history, and the fix on every entry in the encyclopedia.

Sign up free. Unlock the full analysis

No credit card. Daily allowance follows verified trust tier. Instant access.

Diagnose this failure in VS Code

Select the traceback or open the failed terminal, then run Denpex locally to see the initiating rank, collateral failures, exact fix, and verification command without uploading the log.

Install the free VS Code extension

NCCL errors in context

NCCL is where a distributed job reports failure, which is not the same as where it failed. The hub lists every common NCCL error next to what it actually indicates, and the environment variables that tell them apart.

Compare every nccl error side by side

Don't just read the fix, diagnose your run

The encyclopedia tells you what went wrong. Denpex tells you what went wrong in YOUR training run. With your logs, your config, and your stack.